37-630 Intermittent Reception BCB

37-630 Intermittent Reception BCB

Check oscillator transformer connections in this circuit. This is Fig. 5, Service Bulletin No. 251. A high resistance [solder] joint on the connection at the trimmers or padding condensers for this band will have this effect.

From the Philco Serviceman – June, 1937.